Drug-labels.com Search Menu

Sterile Water for Irrigation, USP Product Monograph

Strength:
100 %
Active ingredient:

Product Monograph - Sterile Water for Irrigation, USP

Summary Product Information

Sterile Water for Irrigation, USP is a sterile, nonpyrogenic solution and contains no bacteriostatic or antimicrobial agents or other substance.

Sterile Water for Irrigation, USP is not isotonic and is hemolytic.

The composition, osmolarity and approx. pH of Sterile Water for Irrigation, USP is shown in Table 1.

Table 1Siz e (m L)DINConta in er T y peComp os iti onO s molari ty ( mO s mol/ L)pH
Wat er for Injec t ion , USP
Sterile Water for Irrigation, USP100000799998Uromatic PVC Container100%0

Approx. 5.5

(5.0 to 7.0)

3000
Sterile Water for Irrigation, USP50000799998Plastic Pour Bottle100%0

Approx. 6.0

(5.0 to 7.0)

1000

Uromatic Plastic Container

The Uromatic plastic container is fabricated from a specially formulated polyvinyl chloride.

The amount of water that can permeate from inside the container into the overwrap is insufficient to affect the fluid significantly. Water in contact with the plastic container may leach out certain chemical components from the plastic in very small amounts; however, biological testing was supportive of the safety of the plastic container materials.

Plastic Pour Bottle

The plastic pour bottle container is fabricated from specially formulated polyolefin.

Indications and Clinical Use

Sterile Water for Irrigation, USP is intended for use as an irrigant only.

Contraindications

Not for Injection.

Warnings and Precautions

Warnings

For irrigation only. Not for injection or infusion by usual parenteral routes.

Sterile Water for Irrigation, USP is hypotonic with an osmolarity of zero mOsmol/L. If used for continuous irrigation or allowed to dwell inside body cavities, absorption into the blood stream may occur resulting in hemolysis, therefore use under such conditions is not recommended.

Absorption of water for irrigation (e.g., through perforations, open wounds or body cavities) has resulted in fatal complications or permanent morbidity and use under these conditions is not recommended. Immediate intervention may be required to prevent these outcomes.

  • Absorption can result in hyponatremia, hypoosmolality, as well as fluid overload.
  • Possible complications include, but are not limited, to cerebral edema, encephalopathy, pulmonary edema, massive hemolysis, rhabdomyolysis, renal failure, and hyperkalemia and their secondary manifestations and complications (see ADVERSE REACTIONS).
  • These complications can manifest after irrigation has ended.
  • The development of these complications is dependent on factors such as rate, volume, pressure and duration of irrigation.
  • If absorption of clinically relevant amounts of fluid is suspected, administration should be interrupted and the patient evaluated for signs of fluid absorption.

Close monitoring during and/or after the procedure is required in patients with increased risk for developing hyponatremic encephalopathy, such as:

  • pediatric patients (< 16 years of age)
  • women, in particular premenopausal women
  • patients with hypoxemia
  • patients with underlying central nervous system disease

Close monitoring during and/or after the procedure is required in patients at increased risk for developing a fluid overload syndrome (e.g., patients with severely impaired renal function, impaired cardiac function, or other clinical conditions associated with edematous states). In cases where significant absorption may occur (e.g., transurethral resection of prostate), Sterile Water for Irrigation, USP must, if at all, only be used with extreme caution:

  • Very close monitoring is required during and for an appropriate period after the procedure to allow for timely intervention.

Sterile Water for Irrigation, USP must be used only by physicians familiar with the treatment of possible complications.

Excessive volume or pressure during irrigation may cause undue distention of body cavities, and/or disruption of tissue.

Risk of Air Embolism

Only for Sterile Water for Irrigation, USP in Uromatic Plastic Containers:

The container must not be vented.

Vented administration sets with the vent in the open position should not be used with flexible plastic containers. Use of a vented administration set with the vent in the open position could result in air embolism.

Pressurizing fluids contained in flexible plastic containers to increase flow rates can result in air embolism if the residual air in the container is not fully evacuated prior to use.

Do not connect flexible plastic containers in series in order to avoid air embolism due to possible residual air contained in the primary container.

Precautions

When Sterile Water for Irrigation, USP is used with electrosurgery or cautery, compatibility with the equipment must be ensured.

Only for Sterile Water for Irrigation, USP in Uromatic Plastic Containers:

When using Sterile Water for Irrigation, USP for pour irrigation, prevent contact of the fluid with the external surface of the container.

Only for Sterile Water for Irrigation, USP in Plastic Pour Bottles:

When using Sterile Water for Irrigation, USP for pour irrigation, prevent contact of the fluid with the external surface of the container (including the thread for the bottle cap).

Special Populations

Pediatrics

Safety and effectiveness in pediatric patients have not been established by adequate and well-controlled trials performed by Baxter.

Pediatric patients (< 16 years of age) are at increased risk for developing hyponatremic encephalopathy, even with mild hyponatremia.

Geriatrics

When deciding on volume of irrigant and on duration and pressure of irrigation for a geriatric patient, consider that geriatric patients are more likely to have cardiac, renal, hepatic, and other diseases or concomitant drug therapy.

Pregnancy and Lactation

There are no adequate data from the use of Sterile Water for Irrigation, USP in pregnant or lactating women. Healthcare providers should carefully consider the potential risks and benefits for each specific patient before using Sterile Water for Irrigation, USP.

Adverse Reactions

The list of adverse reactions in this Prescribing Information is based on postmarketing reports (see below).

Post-Market Adverse Drug Reactions

METABOLISM AND NUTRITION DISORDERS: Hyponatremia, Fluid overload, Fluid Absorption, Electrolyte imbalance

NERVOUS SYSTEM DISORDERS: Cerebral edema

GENERAL DISORDERS AND ADMINISTRATION SITE CONDITIONS: Burning sensation (with irrigation of eyes and skin wounds) MUSCULOSKELETAL AND CONNECTIVE TISSUE DISORDERS: Rhabdomyolysis (Myoglobinuria) RENAL AND URINARY DISORDERS: Renal failure

Class Reactions

Adverse reactions which may occur in association with absorption of water for irrigation include:

BLOOD AND LYMPHATIC SYSTEM DISORDERS: Hemolysis (Hemoglobinemia, Hemoglobinuria)

METABOLISM AND NUTRITION DISORDERS: Hypervolemia, Hypoosmolality, Hyperkalemia, Acid/base balance disorder

NERVOUS SYSTEM DISORDERS: Encephalopathy (Convulsion, Loss of vision, Lethargy, Disorientation, Irritability, Vomiting, Nausea, Headache)

CARDIAC DISORDERS: Cardiac arrest, Cardiac failure, Bradycardia, Electrocardiogram abnormal

VASCULAR DISORDERS: Hypertension, Postoperative hypotension

RESPIRATORY, THORACIC AND MEDIASTINAL DISORDERS: Respiratory arrest, Respiratory failure, Pulmonary edema

Dosage and Administration

Volume and/or rate of irrigation depend on the type of the procedure and the capacity or the surface area of the structure to be irrigated.

Sterile Water for Irrigation, USP must not be administered intravenously or by other, usual parenteral routes.

Sterile Water for Irrigation, USP is not intended for oral administration.

Sterile Water for Irrigation, USP should be inspected visually for particulate matter and discoloration prior to use whenever fluid and container permit. Do not use unless the fluid is clear and the seal is intact.

Aseptic technique must be used.

The contents of the opened container should be used immediately to minimize potential for bacterial growth and pyrogen formation, and the unused contents of opened containers must be discarded, since Sterile Water for Irrigation, USP does not contain an antimicrobial agent.

Sterile Water for Irrigation, USP is for single use only.

Microwave heating of irrigation fluids is not recommended.

Sterile Water for Irrigation, USP that has been warmed must not be returned to storage.

Additives may be incompatible with Sterile Water for Irrigation, USP.

Compatibility of additives with Sterile Water for Irrigation, USP must be assessed before addition, by checking for, e.g., a possible color change and/or the appearance of precipitates, insoluble complexes, or crystals.

Before adding a substance or medication, verify that it is soluble and/or stable in water and that the pH range of Sterile Water for Irrigation, USP is appropriate.

The instructions for use of the medication to be added and other relevant literature must be consulted.

Additives known or determined to be incompatible should not be used.

Overdosage

In the event of clinically relevant absorption of Sterile Water for Irrigation, USP, patients must be evaluated and corrective measures instituted as indicated. Immediate intervention may be required to prevent fatal outcomes or permanent morbidity (see WARNINGS AND PRECAUTIONS). Storage

Store at 15oC to 25oC

Special Handling Instructions

When making additions to Sterile Water for Irrigation, USP, aseptic technique must be used.

Mix thoroughly when additives have been introduced.

Do not store Sterile Water for Irrigation, USP containing additives.

Dosage Forms, Composition and Packaging

Table 1 shows the composition, osmolarity, approx pH, calories/litre and available size of Sterile Water for Irrigation, USP.

Directions for use of Uromatic Plastic Container

WARNING: Do not use plastic containers in series connections. Such use could result in air embolism due to residual air (approximately 15 mL) being drawn from the primary container before administration of the fluid from the secondary container is completed.

Do not remove unit from overwrap until ready to use.

To Open

Tear overwrap down side at slit and remove solution container. Visually inspect the container. If the outlet port protector is damaged, detached, or not present, discard container as solution path sterility may be impaired. Some opacity of the plastic due to moisture absorption during sterilization process may be observed. This is normal and does not affect the solution quality and safety. The opacity will diminish gradually. Check for minute leaks by squeezing inner bag firmly. If leaks are found discard solution as sterility may be impaired.

Use Aseptic Technique.

  1. 1. Suspend container using hanger hole.
  2. 2. Remove plastic protector from outlet port at bottom of container.
  3. 3. Attach irrigation set. Refer to complete directions accompanying set.

Control No: 212689

Baxter Corporation

Mississauga, ON L5N 0C2

Baxter is a trademark of Baxter International Inc.

Date of Revision: June 11, 2019

About this document

Source: Health Canada – Drug Product Database (DPD) and product monographs · DIN (Drug Identification Number): 00799998

Found a mistake? Write to us via the contact page.

The information on this site does not replace the advice of a doctor or pharmacist.

Drug information for Sterile Water for Irrigation, USP

DIN 00799998
Schedule(s) ETHICAL
Active ingredient(s) Water 100 %
Dosage form(s) Liquid
Route(s) of administration Irrigation
Company BAXTER CORPORATION
Current status Marketed
Current status date December 8, 2020

Source: Health Canada – Drug Product Database (DPD) and product monographs, data as of November 12, 2026. Data from the Health Canada Drug Product Database, as published there. Not a substitute for the advice of a doctor or pharmacist.