Strength:
12.5 mcg / 12.5 mcg / 12.5 mcg

Product Monograph - Mflusiva

Recent Major Label Changes

Not applicable

Table of Contents

Certain sections or subsections that are not applicable at the time of the preparation of the most recent authorized product monograph are not listed.

Recent Major Label Changes ................................................................................................... 2

Table of Contents ................................................................................................................... 2

Part 1: Healthcare Professional Information ........................................................................... 4

  1. 1.

    Indications ....................................................................................................................... 4

    1.1. Pediatrics .................................................................................................................. 4

    1.2. Geriatrics .................................................................................................................. 4

  2. 2. Contraindications ............................................................................................................ 4
  3. 4.

    Dosage and Administration ............................................................................................. 4

    4.1. Dosing Considerations .............................................................................................. 4

    4.2. Recommended Dose and Dosage Adjustment ......................................................... 4

    4.3. Reconstitution .......................................................................................................... 4

    4.4. Administration .......................................................................................................... 5

  4. 5. Overdose ......................................................................................................................... 5
  5. 6. Dosage Forms, Strengths, Composition, and Packaging ................................................... 5
  6. 7.

    Warnings and Precautions ............................................................................................... 7

    General ................................................................................................................................. 7

    Driving and Operating Machinery ......................................................................................... 7

    Hematologic ......................................................................................................................... 7

    Immune ................................................................................................................................ 7

    Neurologic ............................................................................................................................ 7

    7.1. Special Populations .................................................................................................. 7

    7.1.1. Pregnancy ........................................................................................................ 7

    7.1.2. Breastfeeding .................................................................................................. 7

    7.1.3. Pediatrics ......................................................................................................... 8

    7.1.4. Geriatrics ......................................................................................................... 8

  7. 8.

    Adverse Reactions ........................................................................................................... 8

    8.1. Adverse Reaction Overview ...................................................................................... 8

    8.2. Clinical Trial Adverse Reactions ................................................................................ 8

    8.5. Post-Market Adverse Reactions ............................................................................. 13

  8. 9. Drug Interactions ........................................................................................................... 13
  9. 10.

    Clinical Pharmacology ................................................................................................... 13

    10.1. Mechanism of Action .............................................................................................. 13

  10. 11. Storage, Stability, and Disposal ...................................................................................... 14
  11. 12. Special Handling Instructions ......................................................................................... 14

Part 2: Scientific Information ................................................................................................ 15

  1. 13. Pharmaceutical Information .......................................................................................... 15
  2. 14.

    Clinical Trials .................................................................................................................. 15

    14.1. Clinical Trials by Indication ..................................................................................... 15

    14.1.1. Efficacy and Immunogenicity in Individuals 50 Years of Age and Older ......... 16

  3. 16. Non-Clinical Toxicology .................................................................................................. 19

Patient Medication Information ........................................................................................... 21

Part 1: Healthcare Professional Information

1. Indications

mFLUSIVA (Influenza mRNA vaccine) is indicated for active immunization of adults 50 years of age and older for the prevention of influenza disease caused by influenza virus subtypes A and B represented in the vaccine.

The National Advisory Committee on Immunization (NACI) provides additional guidance on the use of the influenza vaccine in Canada. Please refer to the published Statement on Seasonal Influenza Vaccine for the current season.

1.1. Pediatrics

Pediatrics (<18 years of age): No data are available to Health Canada; therefore, Health Canada has not authorized an indication for pediatric use in children under 18 years of age (see 8 Adverse Reactions, and 14 Clinical Trials).

1.2. Geriatrics

Geriatrics (≥65 years of age): Clinical studies of mFLUSIVA included participants 65 years of age and older, and their data contribute to the overall assessment of the safety and effectiveness of mFLUSIVA (see 8 Adverse Reactions, and 14 Clinical Trials).

2. Contraindications

mFLUSIVA is contraindicated in individuals who are hypersensitive to the active ingredient or to any ingredient in the formulation, including any non-medicinal ingredient, or component of the container.

For a complete listing, see 6 Dosage Forms, Strengths, Composition, and Packaging.

4. Dosage and Administration

4.1. Dosing Considerations

mFLUSIVA is a dispersion in a single-dose, pre-filled syringe for intramuscular injection that should be administered by a trained healthcare professional.

mFLUSIVA is administered as a single dose of 0.38 mL intramuscularly.

4.3. Reconstitution

mFLUSIVA must not be reconstituted, mixed with other medicinal products, or diluted. No dilution is required prior to administration.

4.4. Administration

Preparation

mFLUSIVA is supplied as a dispersion in a pre-filled syringe that does not contain preservative.

Do not shake the pre-filled syringe before use.

The pre-filled syringes may be stored at 8°C to 25°C for a total of 12 hours after removal from refrigerated conditions. Discard the pre-filled syringe if not used within this time. Syringes should not be returned to the refrigerator after being stored at room temperature.

Parenteral drug products should be inspected visually for particulate matter and discolouration prior to administration. mFLUSIVA is a white to off-white dispersion practically free of visible particles. Do not administer if the vaccine is discoloured or contains other particulate matter.

Administration

Administer a single 0.38 mL dose of mFLUSIVA intramuscularly (IM). The preferred site is the deltoid muscle of the upper arm. Do not administer this product intravenously. mFLUSIVA should not be combined through reconstitution or mixed with any other vaccine.

  • Use a sterile needle of the appropriate size for intramuscular injection.
  • With tip cap upright, remove tip cap by twisting counterclockwise until tip cap releases. Remove tip cap in a slow, steady motion. Avoid pulling tip cap while twisting.
  • Attach the needle by twisting in a clockwise direction until the needle fits securely on the pre-filled syringe.
  • Uncap the needle when ready for administration.
  • Administer the entire dose intramuscularly.

Disposal

Discard syringe after use.

5. Overdose

For the most recent information in the management of a suspected drug overdose, contact your regional poison control centre or Health Canada’s toll-free number, 1-844 POISON-X (1-844-764-7669).
  1. 6. Dosage Forms, Strengths, Composition, and Packaging

To help ensure the traceability of vaccines for patient immunization record-keeping as well as safety monitoring, healthcare professionals should record the time and date of administration, quantity of administered dose (if applicable), anatomical site and route of administration, brand name and generic name of the vaccine, the product lot number and expiry date.

Table 1 – Dosage Forms, Strengths, and Composition

Description

mFLUSIVA is provided as a white to off-white, sterile, preservative-free dispersion for intramuscular injection. mFLUSIVA is a messenger ribonucleic acid (mRNA)-based vaccine containing lipid nanoparticle (LNP), comprised of RNA encoding full-length haemagglutinin (HA) glycoproteins of seasonal influenza virus type A (H1N1 and H3N2) and B (Victoria lineage), formulated with the non-medicinal ingredients listed in Table 1.

mFLUSIVA does not contain any preservatives, antibiotics, adjuvants, or human- or animal-derived materials. mFLUSIVA is manufactured using a cell-free and egg-free process.

One 0.38 mL single-dose, pre-filled syringe of mFLUSIVA contains:

12.5 mcg RNA – Influenza Virus A/Wisconsin/67/2022 (A/H1N1)

12.5 mcg RNA – Influenza Virus A/Massachusetts/18/2022 (A/H3N2)

12.5 mcg RNA – Influenza Virus B/Austria/1359417/2021 (B/Victoria lineage)

This vaccine complies with the World Health Organization (WHO) recommendation (Northern Hemisphere) for the Influenza 2024 – 2025 season.

mFLUSIVA is supplied in a single-dose pre-filled syringe with halobutyl rubber tip-cap in rigid plastic cover (without needle). The rubber tip cap and plunger used for the pre-filled syringes are not made with natural rubber latex.

mFLUSIVA is available in cartons containing 1 or 10 single-dose pre-filled syringes.

Route of AdministrationDosage Form/ Strength/CompositionNon-Medicinal Ingredients
Intramuscular injection

Dispersion, (37.5 mcg / 0.38 mL)

Each 0.38 mL dose contains:

  • 12.5 mcg of RNA encoding haemagglutinin of influenza A/H1N1
  • 12.5 mcg of RNA encoding haemagglutinin of influenza A/H3N2
  • 12.5 mcg of RNA encoding haemagglutinin of influenza B/Victoria lineage

Single-dose, pre-filled syringe (0.38 mL)

  • Cholesterol
  • DSPC (1,2-distearoyl-sn-glycero-3-phosphocholine)
  • SM-102 (heptadecan-9-yl 8-{(2-hydroxyethyl)[6-oxo-6-(undecyloxy)hexyl]amino}octanoate)
  • PEG2000-DMG (1,2-dimyristoyl-rac-glycero-3-methoxypolyethylene glycol-2000)
  • Sucrose
  • Trometamol
  • Trometamol hydrochloride
  • Water for Injection

7. Warnings and Precautions

General

As with all injectable vaccines, appropriate medical treatment and supervision must always be readily available in case of a rare anaphylactic event following the administration of the vaccine.

Consideration should be given to postponing immunization in persons with severe febrile illness or severe acute infection. Persons with moderate or severe acute illness should be vaccinated as soon as the acute illness has improved.

Syncope (fainting) may occur in association with administration of injectable vaccines, including mFLUSIVA. Procedures should be in place to avoid injury from fainting and manage syncopal reactions.

Driving and Operating Machinery

No studies on the effects of mFLUSIVA on the ability to drive and use machines have been performed.

mFLUSIVA is unlikely to affect the ability to drive or use machines.

Hematologic

As with other vaccines administered intramuscularly, mFLUSIVA should be given with caution to individuals with thrombocytopenia or any coagulation disorder since bleeding may occur following an intramuscular administration to these individuals.

Immune

As with any vaccine, the administration of mFLUSIVA may not protect all vaccine recipients.

The safety and efficacy of mFLUSIVA have not been assessed in immunocompromised individuals, including those receiving immunosuppressive therapy. These individuals may have a diminished immune response to mFLUSIVA.

Neurologic

If Guillain-Barré syndrome (GBS) has occurred within 6 weeks following previous influenza vaccination, the decision to give mFLUSIVA should be based on careful consideration of the potential benefits and risks.

7.1. Special Populations

7.1.1. Pregnancy

There are no or limited data from the use of mFLUSIVA in pregnant women. Animal studies do not indicate direct or indirect harmful effects with respect to reproductive toxicity (see 16 Non-Clinical Toxicology).

7.1.2. Breastfeeding

It is not known whether mFLUSIVA is excreted in human milk. Precaution should be exercised because many drugs can be excreted in human milk. No human or animal data are available to assess the effects of mFLUSIVA on the breastfed infant or on milk production/excretion.

7.1.3. Pediatrics

Pediatrics (<18 years of age): Based on the data submitted and reviewed by Health Canada, the safety and efficacy of mFLUSIVA in pediatric patients has not been established; therefore, Health Canada has not authorized an indication for pediatric use (see 8 Adverse Reactions, and 14 Clinical Trials).

7.1.4. Geriatrics

Clinical studies of mFLUSIVA included participants 65 years of age and older, and their data contribute to the overall assessment of the safety and effectiveness of mFLUSIVA (see 8 Adverse Reactions, and 14 Clinical Trials).

8. Adverse Reactions

8.1. Adverse Reaction Overview

The safety profile of mFLUSIVA (Influenza mRNA vaccine) in adults 50 years of age and older is based on data generated from the two clinical trials presented below: Study 1 and Study 2.

In Study 1: mRNA-1010-P304 (NCT06602024), mFLUSIVA has been administered to 20,350 participants 50 years of age and older. The most commonly reported (≥10%) adverse reactions were injection site pain (65.8%), fatigue (45.1%), headache (37.8%), myalgia (35.4%), arthralgia (27.8%), chills (22.8%), and axillary (underarm) swelling or tenderness (17.2%).

In Study 2: mRNA-1010-P303 [Part C] (NCT05827978), Moderna messenger ribonucleic acid (mRNA) quadrivalent influenza vaccine has been administered to 1,502 participants 65 years of age and older. The most commonly reported (≥10%) adverse reactions were injection site pain (64.6%), fatigue (44.5%), myalgia (41.7%), headache (39.4%), arthralgia (35.2%), chills (29.5%), axillary (underarm) swelling or tenderness (16.8%), and nausea/vomiting (12.8%).

The safety experience with Moderna mRNA quadrivalent influenza vaccine is relevant to mFLUSIVA (Influenza mRNA vaccine) because both vaccines are manufactured using the same process and have overlapping compositions.

8.2. Clinical Trial Adverse Reactions

Clinical trials are conducted under very specific conditions. Therefore, the frequencies of adverse reactions observed in the clinical trials may not reflect frequencies observed in clinical practice and should not be compared to frequencies reported in clinical trials of another drug.

As discussed above, the safety of mFLUSIVA (Influenza mRNA vaccine) was evaluated in the two studies described below:

mFLUSIVA in Participants 50 Years of Age and Older

Study 1: mRNA-1010-P304 (NCT06602024) was a Phase 3, randomized, double-blind, active-controlled clinical trial conducted in 11 countries in participants 50 years of age and older during the 2024-2025 influenza season. The study included 40,703 participants 50 years of age and older who received either mFLUSIVA (N=20,350) or a standard dose (SD) inactivated influenza vaccine comparator (FLUARIX®, U.S. Licensed manufactured by GlaxoSmithKline Biologicals, or quadrivalent composition of FLUARIX marketed outside the U.S. under a different brand name [referred to as SD comparator hereafter]; N=20,353). Among recipients of mFLUSIVA, 56.6% were female, 82.6% were white, 13.2% were Black or African American, 10.6% were Hispanic or Latino. The median age was 64 years; 52.2% of recipients were aged 50 through 64 years, 36.2% were aged 65 through 74 years and 11.6% were 75 years of age and older. The demographics and baseline characteristics were comparable across mFLUSIVA and SD comparator groups.

Solicited Adverse Reactions

Local and systemic adverse reactions were solicited in an electronic diary for 7 days following injection (i.e., the day of injection and 6 subsequent days) among a subset of 3,015 participants receiving mFLUSIVA and 2,997 participants receiving SD comparator.

The percentage of participants who reported solicited local and systemic adverse reactions are presented in Table 2 and Table 3, respectively. Solicited adverse reactions (any grade, including Grade 3) were reported more frequently in the mFLUSIVA group compared with the SD comparator group.

In the mFLUSIVA group, both local and systemic solicited adverse reactions had a median onset of 2 days after injection and a median duration of 2 days. Most reactions were Grade 1 or Grade 2 in severity. No Grade 4 reactions were reported in the study.

Table 2 – Number and Percentage of Participants in Study 1 (≥50 Years of Age) with Solicited Local Adverse Reactions of Any Grade and Grade 3 Within 7 Days of Vaccination*

Local Adverse Reactions

mFLUSIVA (mRNA-1010 37.5 mcg)

N=3,015 n (%)

SD Comparatora (Influenza Vaccine 45 mcg)

N=2,997 n (%)

Any Grade (%)Grade 3 (%)Any Grade (%)Grade 3 (%)
Injection site painb1,985 (65.8)27 (0.9)894 (29.8)1 (<0.1)
Axillary (underarm) swelling or tendernessb520 (17.2)10 (0.3)184 (6.1)1 (<0.1)
Swelling (hardness)c172 (5.7)9 (0.3)45 (1.5)4 (0.1)
Erythema (redness)c117 (3.9)10 (0.3)38 (1.3)2 (<0.1)

Abbreviations: SD=Standard Dose; N=number of participants in the analysis population; n=number of participants reporting the event; mRNA=messenger ribonucleic acid

* 7 days included day of vaccination and the subsequent 6 days. Events were collected in the electronic diary

(e-diary).

a FLUARIX®, U.S. Licensed manufactured by GlaxoSmithKline Biologicals, or quadrivalent composition of FLUARIX marketed outside the U.S. under a different brand name.

b Pain, and axillary (underarm) swelling or tenderness grading scale: no interference with activity (Grade 1); some interference with activity (Grade 2); prevents daily activity (Grade 3).

c Swelling and erythema grading scale: 25-50 mm / 2.5-5 cm (Grade 1); 51-100 mm / 5.1-10 cm (Grade 2); >100 mm / >10 cm (Grade 3).

Table 3 – Number and Percentage of Participants in Study 1 (≥50 Years of Age) with Solicited Systemic Adverse Reactions of Any Grade and Grade 3 Within 7 Days of Vaccination*

Systemic Adverse Reactions

mFLUSIVA (mRNA-1010 37.5 mcg)

N=3,015 n (%)

SD Comparatora

(Influenza Vaccine 45 mcg)

N=2,997 n (%)

Any Grade (%)Grade 3 (%)Any Grade (%)Grade 3 (%)
Fatigueb1,360 (45.1)97 (3.2)609 (20.3)13 (0.4)
Headacheb1,140 (37.8)59 (2.0)538 (18.0)10 (0.3)
Myalgiab1,067 (35.4)76 (2.5)348 (11.6)7 (0.2)
Arthralgiab839 (27.8)57 (1.9)317 (10.6)6 (0.2)
Chillsb688 (22.8)62 (2.1)129 (4.3)4 (0.1)
Nausea/vomitingc259 (8.6)5 (0.2)102 (3.4)2 (<0.1)
Feverd174 (5.8)17 (0.6)26 (0.9)3 (0.1)

Abbreviations: SD=Standard Dose; N=number of participants in the analysis population; n=number of participants reporting the event; mRNA=messenger ribonucleic acid

* 7 days included day of vaccination and the subsequent 6 days. Events were collected in the electronic diary

(e-diary).

a FLUARIX®, U.S. Licensed manufactured by GlaxoSmithKline Biologicals, or quadrivalent composition of FLUARIX marketed outside the U.S. under a different brand name.

b Fatigue, headache, myalgia, arthralgia, and chills grading scale: no interference with activity (Grade 1); some interference with activity (Grade 2); prevents daily activity (Grade 3).

c Nausea/vomiting grading scale: no interference with activity or 1-2 episodes/24 hours (Grade 1); some interference with activity or >2 episodes/24 hours (Grade 2); prevents daily activity or requires outpatient intravenous hydration (Grade 3).

d Fever grading scale: ≥38.0°C – ≤38.4°C (Grade 1); ≥38.5°C – ≤38.9°C (Grade 2); ≥39.0°C – ≤40.0°C (Grade 3).

Unsolicited Adverse Events

In Study 1, participants were monitored for unsolicited adverse events for 28 days post vaccination. Unsolicited adverse events were reported in 5.9% (1,204/20,350) of participants in the mFLUSIVA group and 5.7% (1,167/20,353) of participants in the SD comparator group. There were no notable patterns or numerical imbalances between treatment groups for specific categories of adverse events that would suggest a causal relationship to mFLUSIVA.

Serious Adverse Events (SAEs)

Serious adverse events (SAEs) were collected for 6 months post vaccination. In Study 1, the median duration of follow-up was 181 days (range 1 to 227 days). SAEs were reported in 2.2% (455/20,350) of participants in the mFLUSIVA group and 1.9% (392/20,353) of participants in the SD comparator group.

In the mFLUSIVA group, on Study Day 2, one serious adverse event of syncope, accompanied by fever and possible dehydration, in a 62-year-old participant, was assessed to be related to the study vaccine.

There were no other notable patterns or numerical imbalances between treatment groups for specific categories of serious adverse events that would suggest a causal relationship to mFLUSIVA.

Moderna mRNA Quadrivalent Influenza Vaccine in Participants 65 Years of Age and Older

Study 2: mRNA-1010-P303 [Part C] (NCT05827978) was a randomized, double-blind, active-controlled study conducted in the United States in adults 65 years of age and older during the 2023-2024 influenza season. The study included 2,992 participants 65 years of age and older to receive either Moderna mRNA quadrivalent influenza vaccine (N=1,502) or High-Dose (HD) inactivated influenza vaccine comparator (Fluzone® HD Quadrivalent, manufactured by Sanofi Pasteur Inc. [referred to as HD comparator hereafter]; N=1,490). Among recipients of Moderna mRNA quadrivalent influenza vaccine, 58.5% were female, 83.6% were white, 14.9% were Black or African American, 30.0% were Hispanic or Latino. The median age was 70.0 years; 78.3% were aged 65 through 74 years and 21.7% were 75 years of age and older.

The demographics and baseline characteristics were comparable across the Moderna mRNA quadrivalent influenza vaccine and the HD comparator groups.

Solicited Adverse Reactions

Local and systemic adverse reactions were solicited in an electronic diary for 7 days following injection (i.e., the day of injection and 6 subsequent days) among participants receiving Moderna mRNA quadrivalent influenza vaccine and participants receiving HD comparator.

The percentage of participants who reported solicited local and systemic adverse reactions are presented in Table 4 and Table 5, respectively. Solicited adverse reactions (any grade, including Grade 3 or 4) were reported more frequently in the Moderna mRNA quadrivalent influenza vaccine group compared with the HD comparator group.

The median time of onset for solicited local adverse reactions after vaccination were Day 2 and Day 1 in the Moderna mRNA quadrivalent influenza vaccine group and the HD comparator group, respectively, and with a median duration of 2 days in both groups. The median time of onset for solicited systemic adverse reactions after vaccination was Day 2 with a median duration of 2 days in both groups. Most reactions were Grade 1 or Grade 2 in severity.

Table 4 – Number and Percentage of Participants in Study 2 (≥65 Years of Age) with Solicited Local Adverse Reactions of Any Grade and ≥Grade 3 Within 7 Days of Vaccination*

Local Adverse Reactions

mRNA QIVa (mRNA-1010 50 mcg)

N=1,502 n (%)

HD Comparatorb (Influenza Vaccine 240 mcg)

N=1,490 n (%)

Local Adverse Reactions

mRNA QIVa (mRNA-1010 50 mcg)

N=1,502 n (%)

HD Comparatorb (Influenza Vaccine 240 mcg)

N=1,490 n (%)

Any Grade (%)Grade 3 (%)Any Grade (%)Grade 3 (%)
Any Grade (%)Grade 3 (%)Any Grade (%)Grade 3 (%)
Injection site painc971 (64.6)23 (1.5)547 (36.7)6 (0.4)
Axillary (underarm) swelling or tendernessc252 (16.8)8 (0.5)128 (8.6)6 (0.4)
Swelling (hardness)d67 (4.5)6 (0.4)25 (1.7)2 (0.1)
Erythema (redness)d42 (2.8)6 (0.4)20 (1.3)3 (0.2)

Abbreviations: HD=High-Dose; N=number of participants in the analysis population; n=number of participants reporting the event; mRNA=messenger ribonucleic acid; QIV=quadrivalent influenza vaccine.

* 7 days included day of vaccination and the subsequent 6 days. Events were collected in the electronic diary

(e-diary).

a An unlicensed Moderna mRNA quadrivalent influenza vaccine manufactured using the same process as mFLUSIVA and differs only in the addition of the RNA encoding the B/Yamagata antigen.

b Fluzone® High-Dose Quadrivalent, U.S. Licensed manufactured by Sanofi Pasteur Inc.

c Pain and axillary swelling or tenderness grading scale: no interference with activity (Grade 1); some interference with activity (Grade 2); prevents daily activity (Grade 3).

d Swelling and erythema grading scale: 25-50 mm / 2.5-5 cm (Grade 1); 51-100 mm / 5.1-10 cm (Grade 2); >100 mm / >10 cm (Grade 3).

Table 5 – Number and Percentage of Participants in Study 2 (≥65 Years of Age) with Solicited Systemic Adverse Reactions of Any Grade and ≥Grade 3 Within 7 Days of Vaccination*

Systemic Adverse Reactions

mRNA QIVa (mRNA-1010 50 mcg)

N=1,502 n (%)

HD Comparatorb (Influenza Vaccine 240 mcg)

N=1,490 n (%)

Any Grade (%)Grade 3 (%)Any Grade (%)Grade 3 (%)
Headachec592 (39.4)35 (2.3)258 (17.3)10 (0.7)
Myalgiac626 (41.7)48 (3.2)239 (16.1)11 (0.7)
Fatiguec669 (44.5)52 (3.5)293 (19.7)12 (0.8)
Arthralgiac529 (35.2)35 (2.3)210 (14.1)11 (0.7)
Chillsc443 (29.5)18 (1.2)115 (7.7)5 (0.3)
Nausea/vomitingd192 (12.8)4 (0.3)63 (4.2)3 (0.2)
Fevere127 (8.5)11 (0.7)f21 (1.4)1 (<0.1)

Abbreviations: HD=High-Dose; N=number of participants in the analysis population; n=number of participants reporting the event; mRNA=messenger ribonucleic acid; QIV=quadrivalent influenza vaccine.

* 7 days included day of vaccination and the subsequent 6 days. Events were collected in the electronic diary

(e-diary).

a An unlicensed Moderna mRNA quadrivalent influenza vaccine manufactured using the same process as mFLUSIVA and differs only in the addition of the RNA encoding the B/Yamagata antigen.

b Fluzone® High-Dose Quadrivalent, U.S. Licensed manufactured by Sanofi Pasteur Inc.

c Headache, myalgia, fatigue, arthralgia, and chills grading scale: no interference with activity (Grade 1); some interference with activity (Grade 2); prevents daily activity (Grade 3).

d Nausea/vomiting grading scale: no interference with activity or 1-2 episodes/24 hours (Grade 1); some interference with activity or >2 episodes/24 hours (Grade 2); prevents daily activity or requires outpatient intravenous hydration (Grade 3).

e Fever grading scale: ≥38.0°C – ≤38.4°C (Grade 1); ≥38.5°C – ≤38.9°C (Grade 2); ≥39.0°C – ≤40.0°C (Grade 3); ≥ 40.1°C (Grade 4).

f Including 2 cases (0.1%) of Grade 4 versus 0 cases in the comparator group.

Unsolicited Adverse Events

In Study 2, unsolicited adverse events within 28 days regardless of relation to study vaccination were reported in 10.3% (155/1,502) of participants in the Moderna mRNA quadrivalent influenza vaccine group and 9.2% (137/1,490) of participants in the HD comparator group. There were no notable patterns or numerical imbalances between treatment groups for specific categories of adverse events that would suggest a causal relationship to Moderna mRNA quadrivalent influenza vaccine.

Serious Adverse Events (SAEs)

In Study 2 with median duration of safety follow-up of 171 days (range 1 – 207 days), SAEs were reported in 2.7% (41/1,502) of participants in the Moderna mRNA quadrivalent influenza vaccine group and 2.6% (38/1,490) of participants in the HD comparator group.

There were no serious adverse events considered causally related to Moderna mRNA quadrivalent influenza vaccine.

There were no notable patterns or numerical imbalances between treatment groups for specific categories of serious adverse events that would suggest a causal relationship to Moderna mRNA quadrivalent influenza vaccine.

8.5. Post-Market Adverse Reactions

There are no post-marketing data available for mFLUSIVA.

9. Drug Interactions

Use with other vaccines

The safety and effectiveness of mFLUSIVA when administered concomitantly with other vaccines has not been assessed.

Do not mix mFLUSIVA with other vaccines/products in the same syringe.

10. Clinical Pharmacology

10.1. Mechanism of Action

mFLUSIVA is a trivalent mRNA influenza vaccine encoding the full-length HA glycoproteins of seasonal influenza virus type A (H1N1 and H3N2) and B (Victoria lineage). After delivery into cells, the mRNA serves as a template for the synthesis of the intended proteins. The expressed, membrane-bound HA glycoproteins of the encoded influenza strains are recognised by immune cells as a foreign antigen, eliciting immune responses, which contribute to protection against influenza.

Annual revaccination is recommended because of changes in circulating strains of influenza virus from year to year. Protection is expected through the influenza season for which the vaccine is indicated.

  1. 11. Storage, Stability, and Disposal

Store refrigerated between 2°C to 8°C. Do not freeze. Do not use after the expiration date shown on the label.

Store in the original package to protect from light.

mFLUSIVA may be stored between 8°C to 25°C for up to 12 hours after removal from refrigerated conditions. Discard the pre-filled syringe if not used within this time. Syringes should not be returned to the refrigerator after being stored at room temperature.

12. Special Handling Instructions

Do not dilute the product.

Do not shake the pre-filled syringe.

Pre-filled syringe should be inspected visually for particulate matter and discolouration prior to administration. mFLUSIVA is a white to off-white dispersion practically free of visible particles. Do not administer if vaccine is discoloured or contains other particulate matter.

mFLUSIVA dispersion for injection does not contain a preservative, is for single use, and should be administered immediately after uncapping.

mFLUSIVA must not be mixed with other medicinal products or diluted.

Any unused mFLUSIVA should be disposed of in accordance with local requirements.

Part 2: Scientific Information

13. Pharmaceutical Information

Drug Substance

Proper name: Influenza mRNA vaccine

Medicinal Ingredients:

mRNA encoding haemagglutinin of influenza A/H1N1, 5′(m7G-5′-ppp- 5′-Gm) cap, 100-nucleotide 3′ poly(A) tail

mRNA encoding haemagglutinin of influenza A/H3N2, 5′(m7G-5′-ppp- 5′-Gm) cap, 100-nucleotide 3′ poly(A) tail

mRNA encoding haemagglutinin of influenza B/Victoria lineage, 5′(m7G-5′-ppp- 5′-Gm) cap, 100-nucleotide 3′ poly(A) tail

Product Characteristics:

mFLUSIVA is manufactured with a cell-free and egg-free process; mRNA including a 5′ cap and poly(A) tail is transcribed in vitro from a DNA template encoding the full-length HA glycoproteins of seasonal influenza virus and purified.

mFLUSIVA is supplied as a sterile, single-dose, ready-to-use dispersion at 37.5 mcg/0.38 mL for intramuscular (IM) administration in a pre-filled syringe (PFS).

14. Clinical Trials

14.1. Clinical Trials by Indication

Table 6 – Summary of Patient Demographics for Clinical Trials in Adults ≥50 years of age

Study #Study designDosage, route of administration and durationStudy subjects (n)Median Age (range)Sex
Study 1: mRNA-1010- P304 (NCT06602024)Phase 3, randomized, double-blind, active-controlled clinical study1 dose of mFLUSIVA, intramuscular injection, month 040,805 Total; 1,258 Canadian participants; (20,402 mFLUSIVA; 20,403 Comparator)64 years (50 to 97)

Females: 56.8%

Males: 43.2%

Study 2:

mRNA-1010-P303 [Part C] (NCT05827978)

Phase 3, randomized, double-blind, active-controlled clinical study1 dose of Moderna mRNA QIV 50 mcg, intramuscular injection, month 03,003 Total (1,507 mRNA-1010; 1,496 Comparator)70 years (64 to 93)

Females: 57.9%

Males: 42.1%

14.1.1. Efficacy and Immunogenicity in Individuals 50 Years of Age and Older

Efficacy in Participants 50 Years of Age and Older

Study 1: mRNA-1010-P304

Study 1 (NCT06602024) was a phase 3, randomized, double-blind, active-controlled clinical study to evaluate the safety and efficacy of mFLUSIVA compared to a SD inactivated influenza vaccine in participants 50 years of age and older during the 2024-2025 influenza season. The clinical trial was conducted in 11 countries: Belgium, Bulgaria, Canada, Estonia, Finland, Georgia, Germany, South Korea, Taiwan, United Kingdom, and United States.

The per-protocol (PP) analysis set for efficacy assessments included 20,179 participants who received mFLUSIVA and 20,124 participants who received a SD comparator influenza vaccine. Among all participants, the median age was 64 years (range: 50 to 97 years), 52.2% were aged 50 to 64 years, 47.8% were 65 years of age and older, 36.2% were aged 65 to 74 years, and 11.6% were 75 years of age and older. Overall, 56.8% participants were female, 82.7% were White, 13.2% were African American, 2.4% were Asian, and 10.4% were Latino/Hispanic ethnicity. A total of 46.8% of participants received seasonal influenza vaccine in the season prior to study enrolment and 56.9% had baseline high-risk factors (i.e., baseline body mass index ≥30 kg/m2 or a medical history of autoimmune/immune-mediated disease, blood disorders, cardiac disorders, diabetes mellitus, hepatic disorders, mental impairment disorders, nervous system disorders, pulmonary disorders, or renal disorders).

The primary efficacy endpoint was real-time reverse transcription polymerase chain reaction (RT-PCR)-confirmed protocol-defined influenza-like illness (ILI) caused by any influenza A or B strains beginning at least 14 days post-vaccination through the end of the influenza season. Protocol-defined ILI included at least 1 systemic symptom (temperature >37.2°C, chills, feverish, tiredness, headaches, or myalgia) and at least 1 respiratory symptom (sore throat, cough, sputum production, wheezing, or difficulty breathing).

mFLUSIVA met all the pre-specified statistical success criteria for relative vaccine efficacy (rVE), including the highest level of pre-specified superiority (super-superiority) with the lower bound of the 95% confidence interval (CI) for the rVE of mFLUSIVA versus SD comparator exceeding 9.1%. Table 7 presents the rVE results for Study 1 based on median duration of follow-up of 181 days (range 1 to 227 days).

Table 7 – Relative Vaccine Efficacy of mFLUSIVA versus SD Comparator against RT-PCR-Confirmed ILI in Adults ≥50 Years of Age (Per-Protocol Analysis Set)

mFLUSIVA

N=20,179

nb (%)

SD Comparatora

N=20,124

nb (%)

rVE

% (95% CI)c

RT-PCR-Confirmed ILI events d411 (2.0)557 (2.8)26.6 (16.7, 35.4)e
Influenza Af386 (1.9)522 (2.6)26.5 (16.1, 35.5)
A (H1N1)223 (1.1)315 (1.6)29.6 (16.4, 40.7)
A (H3N2)158 (0.8)202 (1.0)22.2 (4.3, 36.9)
Influenza Bf,g25 (0.1)35 (0.2)29.1 (-18.5, 57.5)

Abbreviations: CI=confidence interval; ILI=influenza-like illness; RT-PCR=reverse transcription polymerase chain reaction; rVE=relative vaccine efficacy; SD=standard dose, N=number of participants included in the efficacy assessments; n=number of RT-PCR-Confirmed ILI events.

a FLUARIX®, U.S. Licensed manufactured by GlaxoSmithKline Biologicals, or quadrivalent composition of FLUARIX marketed outside the U.S. under a different brand name.

b The event is the first RT-PCR-confirmed protocol-defined ILI that begins at least 14 days after study vaccination through the end of influenza season.

c The rVE and the 95% CI are based on a stratified Cox proportional hazards model.

d Primary endpoint.

e The 3 pre-specified success criteria (sequentially tested) were met (i.e. the lower limit of the 2-sided 95% CI of the vaccine efficacy of mFLUSIVA relative to the licensed SD comparator vaccine was > -10%, >0% and 9.1% for non-inferiority, superiority and super-superiority, respectively).

f The rVE by influenza subtype data were descriptive analyses.

g Cases of influenza B were not distinguished by lineage.

Point estimates of rVE in the subgroup analyses by age, baseline high-risk factors, and prior season influenza vaccination status were generally consistent with rVE of overall population based on PP analysis set (Table 8).

Table 8 – Relative Vaccine Efficacy of mFLUSIVA versus SD Comparator against RT-PCR-Confirmed ILI by Subgroups (Per-Protocol Analysis Set)

Subgroupa

mFLUSIVA

n/N* (%)

SD Comparator

n/N* (%)

rVE

% (95% CI)b

Age group
50 to 64 years229/10,542 (2.2)307/10,501 (2.9)26.1 (12.3, 37.7)
≥65 years182/9,637 (1.9)250/9,623 (2.6)27.4 (12.1, 40.0)
Baseline high-risk factorsc
High-risk241/11,465 (2.1)309/11,457 (2.7)22.3 (8.0, 34.3)
Non high-risk170/8,714 (2.0)248/8,667 (2.9)32.1 (17.5, 44.2)
Influenza vaccination status in previous influenza season
Received238/9,456 (2.5)316/9,421 (3.4)25.2 (11.5, 36.8)
Not received173/10,723 (1.6)241/10,703 (2.3)28.6 (13.2, 41.3)

Abbreviations: CI=confidence interval; ILI=influenza-like illness; RT-PCR=reverse transcription polymerase chain reaction; rVE=relative vaccine efficacy; SD=standard dose.

* Based on the number of participants in each subgroup. The event is the first RT-PCR-confirmed protocol-defined ILI that begins at least 14 days after study vaccination through the end of influenza season, regardless of vaccine match.

a The rVE by subgroups data were descriptive analyses.

b The rVE and the 95% CI are based on stratified Cox proportional hazards model.

c High-risk factors include baseline body mass index ≥30 kg/m2 or having a medical history of autoimmune/immune-mediated disease, blood disorders, cardiac disorders, diabetes mellitus, hepatic disorders, mental impairment disorders, nervous system disorders, pulmonary disorders, or renal disorders.

In a pre-specified exploratory analysis, 22 participants who received mFLUSIVA and 42 participants who received SD comparator required a higher level of care such as hospitalization, emergency room, or urgent care visit (rVE 47.9% [95% CI: 12.8, 68.9]).

Immunogenicity in Participants 65 Years of Age and Older

Study 2: mRNA-1010-P303 [Part C]

Study 2 (NCT05827978) was a randomized, double-blind, active-controlled study conducted in the United States to evaluate the immunogenicity and safety of Moderna mRNA quadrivalent influenza vaccine in adults 65 years of age and older during the 2023-2024 influenza season.

The per-protocol immunogenicity set (PPIS) for the primary analysis included 1,425 participants who received Moderna mRNA quadrivalent influenza vaccine and 1,409 participants who received a HD comparator vaccine. Among all participants, the median age was 70.0 years (range: 65 to 93 years), 57.9% were female, 82.7% were white, 15.3% were African American, 0.7% were Asian, and 30.8% were Latino/Hispanic ethnicity.

Post-vaccination immunogenicity against vaccine-matched influenza strains was evaluated at Day 29 after administration of a single dose of Moderna mRNA quadrivalent influenza vaccine or a HD comparator vaccine. The co-primary endpoints were haemagglutination inhibition (HAI) Geometric Mean Titer (GMT) ratios and the seroconversion rates at Day 29. Pre-specified superiority criteria required that the lower bound of the 97.5% CI of the GMT ratio > 1.0 and the lower bound of the 97.5% CI of the seroconversion rate difference of > 0% for all 8 co-primary endpoints. As shown in Table 9, Moderna mRNA quadrivalent influenza vaccine met the superiority criteria for HAI GMT and seroconversion rates for vaccine-matched influenza strains.

The efficacy experience with Moderna mRNA quadrivalent influenza vaccine is relevant to mFLUSIVA (Influenza mRNA vaccine) because both vaccines are manufactured using the same process and have overlapping compositions.

Table 9 – Post-Vaccination HAI Antibody GMTs and Seroconversion Rates of Moderna mRNA Quadrivalent Influenza Vaccine Relative to HD Comparator at Day 29 in Participants ≥65 Years of Age - PPIS

GMTaGMT RatiobSeroconversioncDifference in seroconversiond
GMTaGMT RatiobSeroconversioncDifference in seroconversiond
mRNA QIVe N=1,425 (95% CI)HD Comparatorf N=1,409 (95% CI)mRNA QIVe over HD Comparator (97.5% CI)mRNA QIVe N=1,425 % (95% CI)HD Comparatorf N=1,409 % (95% CI)mRNA QIV minus HD Comparator (97.5% CI)g
mRNA QIVe N=1,425 (95% CI)HD Comparatorf N=1,409 (95% CI)mRNA QIVe over HD Comparator (97.5% CI)mRNA QIVe N=1,425 % (95% CI)HD Comparatorf N=1,409 % (95% CI)mRNA QIV minus HD Comparator (97.5% CI)g
A/H1N1

174.81

(165.15, 185.04)

130.09

(122.86, 137.74)

1.34

(1.24, 1.45)

49.7

(47.06, 52.31)

36.3

(33.75, 38.84)

13.42

(9.27, 17.52)

A/H3N2

141.62

(133.29, 150.46)

116.24

(109.47, 123.44)

1.21

(1.12, 1.32)

56.4

(53.80, 59.02)

47.8

(45.20, 50.48)

8.59

(4.38, 12.76)

B/Victoria

248.03

(237.34, 259.21)

195.97

(187.44, 204.89)

1.25

(1.18, 1.33)

29.8

(27.46, 32.27)

20.2

(18.09, 22.35)

9.67

(6.04, 13.29)

B/Yamagata

104.82

(100.70, 109.11)

91.94

(88.33, 95.71)

1.14

(1.08, 1.21)

26.0

(23.77, 28.40)

20.2

(18.09, 22.35)

5.88

(2.33, 9.42)

Abbreviations: ANCOVA=analysis of covariance; CI=confidence interval; GMT=geometric mean titre; HAI=haemagglutination inhibition; HD=High-Dose; mRNA=messenger ribonucleic acid; QIV=quadrivalent; PPIS=per-protocol immunogenicity set.

a GMT and 95% CI are calculated based on the t-distribution of the log-transformed HAI antibody titer, then back transformed to the original scale.

b The model-based GMT ratio and 97.5% CI are obtained from an ANCOVA analysis of the log-transformed HAI antibody titer, then back transformed to the original scale.

c The rate of seroconversion is defined as the percentage of participants with a baseline HAI titer <1:10 and a post baseline titer >=1:40 or a baseline HAI titer >=1:10 and a minimum 4-fold rise in post-baseline HAI antibody titer. The 95% CI is calculated using the Clopper-Pearson method.

d The 97.5% CIs are calculated using the Miettinen-Nurminen (score) method.

e An unlicensed Moderna mRNA quadrivalent influenza vaccine manufactured using the same process as mFLUSIVA and differs only in the addition of the RNA encoding the B/Yamagata antigen.

f Fluzone® High-Dose Quadrivalent, U.S. Licensed manufactured by Sanofi Pasteur Inc.

g 97.5% CI is used for GMT ratio and seroconversion rate due to the prespecified multiplicity adjustment procedure.

16. Non-Clinical Toxicology

Non-clinical data reveal no special hazard for humans based on conventional studies of repeat dose toxicity, genotoxicity, developmental and reproductive toxicity.

General toxicology

General toxicity studies were conducted in Sprague Dawley rats following intramuscular administration. Moderna mRNA quadrivalent influenza vaccines were administered at doses up to 100 mcg, with up to two doses given 3 weeks apart. Related vaccine drug products used to support mFLUSIVA were administered intramuscularly at doses up to 150 mcg/dose for up to four administrations once every 2 weeks. Transient and reversible injection site edema and erythema and transient and reversible changes in laboratory tests consistent with a local and/or systemic inflammatory response (including increases in white blood cells, neutrophils, eosinophils, fibrinogen, activated partial thromboplastin time, and globulin, along with the decreases in albumin and reticulocytes) were observed. Across general toxicity studies supporting mFLUSIVA, the no-observed adverse-effect level (NOAEL) was the highest dose examined (150 mcg). Results suggest the toxicity potential to humans is low.

Genotoxicity/carcinogenicity

In vitro genotoxicity studies were conducted with the lipid components of mFLUSIVA, SM-102 and PEG2000-DMG. In vivo genotoxicity studies were conducted in Sprague Dawley rats with related vaccine drug products following IV administration. Results suggest the genotoxicity potential to humans is very low. Carcinogenicity studies were not performed.

Reproductive and developmental toxicology

There are no data on the effects of mFLUSIVA on human fertility. Animal studies with mFLUSIVA do not indicate direct or indirect harmful effects with respect to reproductive toxicity. The completed animal studies were insufficient to assess effects on male reproductive function, however, general toxicity studies conducted in Sprague Dawley rats indicate a low risk to reproductive organs based on histopathological data generated with Moderna mRNA quadrivalent influenza vaccines or related vaccine products (see General Toxicology above).

In a combined female fertility and developmental toxicity study, Moderna mRNA quadrivalent influenza vaccine (100 mcg) was administered to female Sprague Dawley rats by the intramuscular route on four occasions: 28 and 14 days prior to mating, and on gestation days 1 and 13. Haemagglutinin antibody responses were present in maternal animals from prior to mating to the end of the study on lactation day 21 as well as in fetuses, offspring, and milk. There were no vaccine-related adverse effects on female fertility, pregnancy, embryo fetal or offspring development or postnatal development, therefore the NOAEL was 100 mcg.

About this document

Source: Health Canada – Drug Product Database (DPD) and product monographs · DIN (Drug Identification Number): 02573245

Found a mistake? Write to us via the contact page.

The information on this site does not replace the advice of a doctor or pharmacist.

Drug information for Mflusiva

DIN 02573245
Schedule(s) SCHEDULE D
Active ingredient(s) *Influenza a/h1n1 MRNA, 5?(m7g-5?-ppp-5?-gm) cap, 3? poly(a) tail 12.5 MCG, *Influenza a/h3n2 MRNA, 5?(m7g-5?-ppp-5?-gm) cap, 3? poly(a) tail 12.5 MCG, *Influenza b/victoria MRNA, 5?(m7g-5?-ppp-5?-gm) cap, 3? poly(a) tail 12.5 MCG
Dosage form(s) Dispersion
Route(s) of administration Intramuscular
Drug class (WHO ATC)
  1. J Antiinfectives for systemic use
    1. J07 Vaccines
      1. J07B Viral vaccines
        1. J07BB Influenza vaccines
          1. J07BB05 Influenza, rna-based vaccines
Company MODERNA BIOPHARMA CANADA CORPORATION
Current status Approved
Current status date November 4, 2026